دوره 3، شماره 4 - ( زمستان 1392 1392 )                   جلد 3 شماره 4 صفحات 34-29 | برگشت به فهرست نسخه ها

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

najafi L, mostamand J, amiri A, mahaki B. Reliability of Ground reaction force measurement during lower extremity perturbation in single leg standing . PTJ 2014; 3 (4) :29-34
URL: http://ptj.uswr.ac.ir/article-1-114-fa.html
نجفی لیلا، مستمند جاوید، امیری علی، مهکی بهزاد. Reliability of Ground reaction force measurement during lower extremity perturbation in single leg standing . فصلنامه فیزیک درمانی. 1392; 3 (4) :29-34

URL: http://ptj.uswr.ac.ir/article-1-114-fa.html


1- علوم پزشکی اصفهان
2- علوم پزشکی ایران
چکیده:   (5577 مشاهده)
Introduction: The aim of the current study was to measure ground reaction force and center of pressure (COP) during lower extremity perturbation in single leg standing whit knee flexion and extension in healthy subjects, in addition to revealing reliability of the device used for the related perturbation for using another studies, reliability is one of the characteristic of measuring instrument , this indicates that measuring instrument to what extent in the same conditions gives the same results. Materials and method: perturbation device was built firstly, rotational perturbation (trunk and femur rotation on weigh bearing tibia ) were applied to the dominant leg of 13 healthy subjects during single leg standing . Four models of rotational perturbation (external and internal tibial rotation with knee flexion and extension) were applied to the lower extremities to collect ground reaction force and centre of pressure in these subjects. Subjects attached to lower extremity perturbation device and standing whit single leg on force plate. Subjects were then asked to repeat the tests procedure after a week’s interval. Results: The intra class correlation coefficient and Cronbanch's Alpha values during within and between sessions tests for four models of rotational distributions showed the relatively high reliability of these measurements during single leg standing , the intra class correlation coefficient exceeded 0.7 in all dominants. Conclusion: The relatively high reliability of ground reaction force and centre of pressure measurements during four different perturbations of external and internal tibial rotation with knee flexion and extension in healthy subjects suggests that these measurements can be used during single leg standing in future studies.
متن کامل [PDF 454 kb]   (1428 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: تخصصي
دریافت: 1392/11/17 | پذیرش: 1392/12/13 | انتشار: 1393/2/17

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

ارسال پیام به نویسنده مسئول


بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به فیزیک درمانی- نشریه تخصصی فیزیوتراپی می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Physical Treatments - Specific Physical Therapy Journal

Designed & Developed by : Yektaweb