دوره 5، شماره 3 - ( Autumn 2015-- 1394 )                   جلد 5 شماره 3 صفحات 144-137 | برگشت به فهرست نسخه ها


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Sadeghi R, Mosallanezhad Z, Nodehi-Moghadam A, Nourbakhsh M R, Biglarian A, Ezati K. The Reliability of Bubble Inclinometer and Tape Measure in Determining Lumbar Spine Range of Motion in Healthy Individuals and Patients. PTJ 2015; 5 (3) :137-144
URL: http://ptj.uswr.ac.ir/article-1-261-fa.html
The Reliability of Bubble Inclinometer and Tape Measure in Determining Lumbar Spine Range of Motion in Healthy Individuals and Patients. فصلنامه فیزیک درمانی. 1394; 5 (3) :137-144

URL: http://ptj.uswr.ac.ir/article-1-261-fa.html


چکیده:   (6787 مشاهده)

Purpose: Regarding the high prevalence of low back pain in various communities and the need to determine an appropriate treatment plan for these patients, examining their functional limitation and disability level is of utmost importance. In this regard, one of the important indicators is Lumbar range of motion. Measurement of the range of motion is a common and appropriate method for determining the functional limitation of the spine and also to examine the effectiveness of various therapeutic interventions. This study was conducted with the purpose of examining the reliability of measuring lumbar range of motion using bubble inclinometer and tape measure.

Methods: This methodological study was performed on 20 healthy males (29–52 years old) and 13 male patients with chronic non-specific low back pain (30–58 years old) in 2015. The ranges of lumbar forward and backward and side bending were measured with bubble inclinometer and rotation with tape measure for both groups. Two measurements were conducted in one day with an interval of one hour to examine the within day reliability, and a third measurement was conducted one week later to examine the between days reliability. Statistical inference was made through calculation of intraclass correlation coefficients (ICC) and standard error of measurement (SEM). All data analysis was done by SPSS version 18.

Results: The ICC and SEM values related to the within days and between days reliability were acceptable. The within day and between days ICC range were 0.770–0.982 and 0.835– 0.977, respectively. SEM range was 0.38–1.20. However, the results of the reliability values of between days measuring of extension in prone position, by using bubble inclinometer, in patients with slight low back pain were low (ICC=0.177 and SEM=5.35).

Conclusion: Results of the present study showed that measuring the lumbar range of motion with bubble inclinometer and tape measure (except measuring extension in prone position by using bubble inclinometer in patients with low back pain) was highly reliable. Therefore, these 2 non-invasive and reliable tools can be used to measure the lumbar range of motion and also to follow-up the effectiveness of therapeutic interventions.

متن کامل [PDF 645 kb]   (5652 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: تخصصي
دریافت: 1394/1/11 | پذیرش: 1394/5/16 | انتشار: 1394/7/9

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به فیزیک درمانی- نشریه تخصصی فیزیوتراپی می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Physical Treatments - Specific Physical Therapy Journal

Designed & Developed by : Yektaweb