دوره 14، شماره 3 - ( 4-1403 )                   جلد 14 شماره 3 صفحات 0-0 | برگشت به فهرست نسخه ها


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Samiei A, Hosseinifar M, Qiasi F, Namvar H, Askary Ashtiyani A. Intra-and Inter-Rater Reliability of the Ultrasonography Measurement of the Cross-Section of the Longus Colli Muscle in Patients with Chronic Non-Specific Neck Pain. PTJ 2024; 14 (3)
URL: http://ptj.uswr.ac.ir/article-1-615-fa.html
Intra-and Inter-Rater Reliability of the Ultrasonography Measurement of the Cross-Section of the Longus Colli Muscle in Patients with Chronic Non-Specific Neck Pain. فصلنامه فیزیک درمانی. 1403; 14 (3)

URL: http://ptj.uswr.ac.ir/article-1-615-fa.html


چکیده:   (258 مشاهده)
Background: Ultrasonography (US) can be used to measure the dimensions and the cross-section of muscles. This study aimed to investigate the intra- and inter-rater reliability of the US measures of the cross-section of the longus colli muscle at rest and in contraction states in patients with chronic nonspecific neck pain (CNSNP) and healthy subjects.
Methods: This cross-sectional study was carried out on seven healthy subjects and seven patients with chronic non-specific pains. The cross-section of the longus colli (LC) muscle was measured at rest and in contraction states at the C5-6 vertebrae by two raters using US on two consecutive days. The data were analyzed by the Pearson Correlation Coefficient (ICC).
Findings: The intra-rater reliability was excellent in the healthy (ICC > 0.97) and patient (ICC > 0.095) groups at rest and in contraction. The inter-rater reliability was excellent in the healthy group (ICC > 0.97) in both states and at rest (ICC = 0.98) and in the contraction (ICC > 0.95) in the patient group.
Conclusion: The findings revealed that US demonstrated higher agreement in measuring the cross-section of the LC in healthy subjects and patients with CNSNP. Thus, this method is reliable and can be used to measure the cross-section of the muscles.
     
نوع مطالعه: كاربردي | موضوع مقاله: تخصصي
دریافت: 1402/8/30 | پذیرش: 1403/3/16 | انتشار: 1403/5/4

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به فیزیک درمانی- نشریه تخصصی فیزیوتراپی می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Physical Treatments - Specific Physical Therapy Journal

Designed & Developed by : Yektaweb